TopTac fabricates and installs steel balconies, balustrades and stairs for main contractors and developers, to the engineer's and architect's design. This page sets out the Building Regulations that shape a balcony, the remediation context for older apartments, and what we need to price.

Steel balconies fabricated and fitted by TopTac in Dun Laoghaire

Guarding heights (Part K)

Requirement K2 of the Building Regulations says the sides of every floor, balcony and part of a roof to which people normally have access must be guarded to protect users from falling. TGD K (2014) Diagram 6 gives guarding heights: 900 mm on stair flights and 1100 mm elsewhere, such as balconies, landings and floor edges, with strength to I.S. EN 1991-1-1 and its Irish National Annex.

TGD K also says that in buildings likely to be used by children under five, a 100 mm sphere should not pass through any opening in the guarding, guarding should not be readily climbable, and footholds such as horizontal rails should be avoided. Glazing in guarding should be safety glazing.

Fire safety (Part B)

Balconies are part of the building's fire strategy. The fire safety designer sets what the balcony is made of, how it relates to escape routes and how it connects through the external wall. A Fire Safety Certificate is needed for new buildings and many alterations, including material alterations of a building containing a flat, under Article 11 of the Building Control Regulations. Steel balconies are non-combustible, but decking, soffits and screens need to meet the specified fire performance too.

Older apartments: the remediation context

Many apartments and duplexes built in Ireland between 1991 and 2013 have fire safety defects. The Housing Agency runs the Interim Remediation Scheme for Fire Safety Defects in Eligible Apartments and Duplexes (2023), which funds emergency fire safety works such as improved detection and alarms, fire safety management and temporary fire-resisting construction. Applications come from owners' management companies, not individual owners.

The Housing Agency says full remedial works, including structural and water-ingress defects, are to be funded under a separate statutory scheme. Check the Housing Agency for the current position. Where remediation includes replacing or repairing balconies, TopTac can fabricate and install new steelwork to the remediation designer's drawings.

Structure and EN 1090

A balcony is a structural element: the engineer designs the frame, the connections back to the building and the thermal break detail, and specifies the Execution Class. Structural steel must be CE marked to EN 1090-1. TopTac is certified to EN 1090 up to Execution Class 2, which Engineers Ireland describes as appropriate for most buildings in Ireland. See EN 1090 explained.

Finish and durability

External balconies are usually hot-dip galvanised and then painted or powder coated. Tell us the specified system, colour and any coastal exposure. Bolted connections keep site welding to a minimum, which protects the galvanised coating.

What we need to price

  • Architectural and structural drawings, and the steel specification including the Execution Class.
  • The number of balconies and how many types.
  • The finish, decking and balustrade infill (glass, bars or mesh).
  • The connection detail to the building and who supplies the fixings and thermal breaks.
  • The programme, site access and lifting arrangements.

What TopTac does

TopTac fabricates balcony frames, balustrades, handrails and stairs in Drogheda and installs them on site, to the engineer's and architect's design. We do not provide the structural or fire design. See balconies.

Sources and further reading

General information, not legal or engineering advice. Check with your engineer, architect or local authority.

Information checked against the official sources below in November 2026. Rules change, so check the current version.

Next step

Pricing balconies?

Send the drawings, the number of units and the programme.

Questions

Common questions

What height should balcony guarding be in Ireland?
TGD K (2014) Diagram 6 gives 1100 mm at balconies, landings and floor edges, and 900 mm on stair flights. Your designer confirms what applies.
Are your balconies CE marked?
Structural steel we fabricate is made under our EN 1090 Factory Production Control, certified up to Execution Class 2, and supplied with a Declaration of Performance where it applies.
Can you replace balconies on an older apartment block?
Yes, to the remediation designer's drawings. Funding questions are for the owners' management company and the Housing Agency.
Do you install as well as fabricate?
Yes. We fabricate in Drogheda and install on site, working to the main contractor's programme.

Pricing balconies?

Send the drawings, the number of units and the programme.

EN 1090 certified for structural steel up to Execution Class 2 (Vinçotte)Made in our workshop in Drogheda, Co. Louth, Ireland